The flexible miniature microphone system for professional users. A comprehensive selection of accessories permits adaptation to a wide range of requirements. Seven different capsules are available.
|
|
Technical Data KM 120, KM 130, KM 131
|
KM 120 |
KM 130 |
KM 131 |
| Acoustical operating principle |
Press. grad. transducer |
Pressure transducer |
Pressure transducer |
| Directional pattern |
Side-fire figure-8 |
Omni diff. field eq |
Omni free field eq |
| Frequency range |
20 Hz ... 20 kHz |
20 Hz ... 20 kHz |
20 Hz ... 20 kHz |
| Sensitivity at 1 kHz into 1 kohm |
12 mV/Pa |
12 mV/Pa |
12 mV/Pa |
| Rated impedance |
50 ohms |
50 ohms |
50 ohms |
| Rated load impedance |
1 kohms |
1 kohms |
1 kohms |
| Equivalent noise level, CCIR1) |
26 dB |
27 dB |
25 dB |
| Equivalent noise level, A-weighted1) |
17.5 dB-A |
16 dB-A |
16 dB-A |
| Signal-to-noise ratio, CCIR1) (rel. 94 dB SPL) |
68 dB |
67 dB |
69 dB |
| Signal-to-noise ratio, A-weighted1) (rel. 94 dB SPL) |
76.5 dB |
78 dB |
78 dB |
| Maximum SPL for THD 0.5%2) |
140 dB |
140 dB |
140 dB |
| Maximum SPL for THD 0.5% with preattenuation2) |
150 dB |
150 dB |
150 dB |
| Maximum output voltage |
10 dBu |
10 dBu |
10 dBu |
| Dynamic range of the microphone amplifier (A-weighted) |
122.5 dB |
124 dB |
124 dB |
| Supply voltage (P48, IEC 61938) |
48 V ± 4 V |
48 V ± 4 V |
48 V ± 4 V |
| Current consumption (P48, IEC 61938) |
2 mA |
2 mA |
2 mA |
| Matching connector |
XLR3F |
XLR3F |
XLR3F |
| Weight |
102 g |
80 g |
80 g |
| Diameter |
24/22 mm |
22 mm |
22 mm |
| Length |
110 mm |
92 mm |
92 mm |
Technical Data KM 140, KM 143
|
KM 140 |
KM 143 |
| Acoustical operating principle |
Press. grad. transducer |
Press. grad. transducer |
| Directional pattern |
Cardioid |
Cardioid wide angle |
| Frequency range |
20 Hz ... 20 kHz |
20 Hz ... 20 kHz |
| Sensitivity at 1 kHz into 1 kohm |
15 mV/Pa |
15 mV/Pa |
| Rated impedance |
50 ohms |
50 ohms |
| Rated load impedance |
1 kohms |
1 kohms |
| Equivalent noise level, CCIR1) |
25 dB |
25 dB |
| Equivalent noise level, A-weighted1) |
16 dB-A |
16 dB-A |
| Signal-to-noise ratio, CCIR1) (rel. 94 dB SPL) |
69 dB |
69 dB |
| Signal-to-noise ratio, A-weighted1) (rel. 94 dB SPL) |
78 dB |
78 dB |
| Maximum SPL for THD 0.5%2) |
138 dB |
138 dB |
| Maximum SPL for THD 0.5% with preattenuation2) |
148 dB |
148 dB |
| Maximum output voltage |
10 dBu |
10 dBu |
| Dynamic range of the microphone amplifier (A-weighted) |
122 dB |
122 dB |
| Supply voltage (P48, IEC 61938) |
48 V ± 4 V |
48 V ± 4 V |
| Current consumption (P48, IEC 61938) |
2 mA |
2 mA |
| Matching connector |
XLR3F |
XLR3F |
| Weight |
80 g |
80 g |
| Diameter |
22 mm |
22 mm |
| Length |
92 mm |
92 mm |
Technical Data KM 145, KM 150
|
KM 145 |
KM 150 |
| Acoustical operating principle |
Press. grad. transducer |
Press. grad. transducer |
| Directional pattern |
Cardioid with low frequency roll-off |
Hypercardioid |
| Frequency range |
20 Hz ... 20 kHz |
20 Hz ... 20 kHz |
| Sensitivity at 1 kHz into 1 kohm |
14 mV/Pa |
10 mV/Pa |
| Rated impedance |
50 ohms |
50 ohms |
| Rated load impedance |
1 kohms |
1 kohms |
| Equivalent noise level, CCIR1) |
26 dB |
27 dB |
| Equivalent noise level, A-weighted1) |
17 dB-A |
18 dB-A |
| Signal-to-noise ratio, CCIR1) (rel. 94 dB SPL) |
68 dB |
67 dB |
| Signal-to-noise ratio, A-weighted1) (rel. 94 dB SPL) |
77 dB |
76 dB |
| Maximum SPL for THD 0.5%2) |
138 dB |
142 dB |
| Maximum SPL for THD 0.5% with preattenuation2) |
148 dB |
152 dB |
| Maximum output voltage |
10 dBu |
10 dBu |
| Dynamic range of the microphone amplifier (A-weighted) |
121 dB |
124 dB |
| Supply voltage (P48, IEC 61938) |
48 V ± 4 V |
48 V ± 4 V |
| Current consumption (P48, IEC 61938) |
2 mA |
2 mA |
| Matching connector |
XLR3F |
XLR3F |
| Weight |
80 g |
80 g |
| Diameter |
22 mm |
22 mm |
| Length |
92 mm |
92 mm |
|
______________________________________________ 1) according to IEC 60268-1; CCIR-weighting acccording to CCIR 468-3, quasi peak; A-weighting according to IEC 61672-1, RMS 2) measured as equivalent el. input signal |
|
|
|