Studio microphone with Retro look. Warm sound, optimized for vocal recordings. Uses the capsule of the legendary M 49 and U 47. Cardioid polar pattern. Set includes elastic suspension.
|
|
| Acoustical operating principle |
Pressure gradient transducer |
| Directional pattern |
Cardioid |
| Frequency range |
20 Hz ... 20 kHz |
| Sensitivity at 1 kHz into 1 kohm |
13 mV/Pa |
| Rated impedance |
50 ohms |
| Rated load impedance |
1 kohms |
| Equivalent noise level, CCIR1) |
23 dB |
| Equivalent noise level, A-weighted1) |
12 dB-A |
| Signal-to-noise ratio, CCIR1) (rel. 94 dB SPL) |
71 dB |
| Signal-to-noise ratio, A-weighted1) (rel. 94 dB SPL) |
82 dB |
| Maximum SPL for THD < 0.5 %2) |
110 dB |
| Maximum SPL for THD < 5 %2) |
129 dB |
| Maximum output voltage for THD < 5%2) |
-1 dBu |
| Dyn. range of the mic. amplifier /A-weighted, 0.5 %2)) |
98 dB |
| Dyn. range of the mic. amplifier /A-weighted, 5 %2)) |
117 dB |
| Supply voltage (P48, IEC 61938) |
48 V ± 4 V |
| Current consumption (P48, IEC 61938) |
3.2 mA |
| Matching connector |
XLR 3F |
| Weight |
825 g |
| Diameter |
78 mm |
| Length |
165 mm |
|
______________________________________________ 1) according to IEC 60268-1; CCIR-weighting acccording to CCIR 468-3, quasi peak; A-weighting according to IEC 61672-1, RMS 2) measured as equivalent el. input signal, k2 dominant |
|
|
|